Honeywell DR4300 Work Light User Manual


 
Troubleshooting and Pen Alignment
of Recorder with Display
12/03 DR4300 Circular Chart Recorder Product Manual 183
8.5.4 Chart Rotation Troubleshooting
Procedure
Table 8-8 explains how to troubleshoot a chart rotation problem.
Table 8-8 Troubleshooting Chart Rotation Failure Symptoms
Step What to do How to do it or
where to find the instructions
1
Check the chart installation. Turn the chart until the desired time line on the
chart is aligned with the time index on the chart
plate and pen 1 before closing the locking clip on
the hub. Push down on the lifter to return the
pen(s) to the chart.
CAUTION: Do not try to rotate the hub
2
Check the configured chart speed value
and change it, if required.
Refer to Section 4 – Configuration, Startup, and
Operation of Recorder with Display.
3
Run the step test. Refer to Section 4 – Configuration, Startup, and
Operation of Recorder with Display (Subsection
4.4.3).
4
Check the motor cable plug connection at
connector P3 on the printed circuit
assembly for pen 1.
Power down the recorder, then visually examine
the plug and re-seat it.
5
Replace the chart motor. Refer to the replacement procedure in Section 9
– Replacing Hardware Assemblies.
6
Replace the printed circuit board for pen
1.
Refer to the replacement procedure in Section 9
– Replacing Hardware Assemblies.