Honeywell DR4300 Work Light User Manual


 
Configuration, Startup, and Operation
of Recorder without Display
12/03 DR4300 Circular Chart Recorder Product Manual 55
= off= on
Any RTD marked with an asterisk is IEC Alpha = 0.00391
All other RTDs are IEC Alpha = 0.00385
in column for SW6 switch 2 = see Subsection 3.2.2
Input
Type
Chart Type Con-
fig #
EU Non-
Lin
CONFIG Switches
(SW1)
INPUT Switches
(SW6)
Chart Part
Number
R56
***
1 2 3 4 5 6 7 8 1 2 3 4 5 6
K t/c
0 to 600 Even
24 Hr
168 °C
1660-052 in
K t/c
0 to 600 Even
24 Hr
246 °F
1660-052 in
K t/c
0 to 600 Even
7 Day
247 °F
in
K t/c
0 to 800 °C
24 Hr
61 x
1660-060 in
K t/c
0 to 800 Even
24 Hr
171 °F
1660-137 in
K t/c
0 to 800 Even
24 Hr
248 °C
1660-137 in
K t/c
0 to 1000 °F
24 Hr
62 x
1660-007 in
K t/c
0 to 1000 °C
24 Hr
65 x
1660-049 in
K t/c
0 to 1000 °C
7 Day
66 x
1661-049 in
K t/c
0 to 1000 °F
7 Day
96 x
1661-016 in
K t/c
0 to 1000 Even
24 Hr
174 °F
1660-173 in
K t/c
0 to 1000 Even
24 Hr
175 °C
1660-173 in
K t/c
0 to 1200 °F
24 Hr
68 x
1660-006 in
K t/c
0 to 1200 °C
24 Hr
69 x
1660-065 in
K t/c
0 to 1200 °F
7 Day
71 x
1661-012 in
K t/c
0 to 1200 Even
24 Hr
176 °C
in
K t/c
0 to 1200 Even
7 Day
177 °F
1661-108 in
K t/c
0 to 1200 Even
7 Day
235 °C
1661-108 in
K t/c
–18 to 1320 °C
7 Day
105 x
1661-031 in
K t/c
0 to 1600 °F
24 Hr
73 x
1660-016 in
K t/c
0 to 1600 °F
7 Day
74 x
1661-013 in
K t/c
0 to 1600 Even
7 Day
180 °F
1661-109 in
K t/c
1200 to 1600 °F
24 Hr
268 x
1660-164 out
6
5
4
3
2
1
INPUT SWITCHES
ON
8
7
6
5
4
3
2
1
CONFIG SWITCHES
ON