Honeywell DR4300 Work Light User Manual


 
DR4300 Circular Chart Recorder
56 DR4300 Circular Chart Recorder Product Manual 12/03
= off= on
Any RTD marked with an asterisk is IEC Alpha = 0.00391
All other RTDs are IEC Alpha = 0.00385
in column for SW6 switch 2 = see Subsection 3.2.2
Input
Type
Chart Type Con-
fig #
EU Non-
Lin
CONFIG Switches
(SW1)
INPUT Switches
(SW6)
Chart Part
Number
R56
***
1 2 3 4 5 6 7 8 1 2 3 4 5 6
K t/c
0 to 2000 °F
24 Hr
79 x
1660-005 in
K t/c
0 to 2000 °F
7 Day
80 x
1661-014 in
K t/c
0 to 2000 Even
24 Hr
236 °F
1660-202 in
K t/c
0 to 2400 °F
24 Hr
81 x
1660-009 in
K t/c
0 to 2400 °F
7 Day
82 x
1661-015 in
K t/c
0 to 2500 Even
24 Hr
185 °F
1660-113 in
R t/c
0 to 1600 °C
24 Hr
75 x
1660-017 in
R t/c
0 to 1600 Even
7 Day
181 °C
1661-109 in
R t/c
800 to 1600 °C
24 Hr
106 x
1660-089 in
R t/c
0 to 2000 Even
24 Hr
183 °F
1660-202 in
R t/c
0 to 2500 °F
24 Hr
83 x
1660-025 in
R t/c
0 to 2500 °F
7 Day
84 x
1661-025 in
R t/c
30 to 2900 °F
24 Hr
85 x
1660-032 in
R t/c
30 to 2900 °F
7 Day
86 x
1661-032 in
Rem
SW1
Digital Pen
(off=90%, on
=95%)
253
in
Rem
SW2
Digital Pen
(off=80%, on=85%)
254
in
RTD
–80 to 20 Even
7 Day
199 °C
1661-653
(dual range chart)
in
RTD*
–50 to 25 °C
24 Hr
259 x
1660-048 out
RTD*
–50 to 25 °C
7 Day
260 x
1661-048 out
RTD
–25 to 25 Even
7 Day
308 °C
out
RTD*
–100 to 50 °C
24 Hr
261 x
1660-091 out
RTD
–50 to 50 °C
24 Hr
19 x
in
6
5
4
3
2
1
INPUT SWITCHES
ON
8
7
6
5
4
3
2
1
CONFIG SWITCHES
ON