Topcom X20 Paint Sprayer User Manual


 
Setup Options- Tanks
44-RRaavveenn-
Select ‘Raven’ if the sprayer has a Raven Fast Flow regulator valve fitted.
Note: Unless a KEE part number: 495181 ( KEE Pressure Relief) has been fitted to the Raven
Fast Flow regulator valve. See Section 22 for more information.
The Raven Fast Flow, has a three way valve, which acts as both regulator and dump valve. The
valve will go from fully closed to open in 1.5.seconds. The PWM Setting must left on FULL
(100%) otherwise this will impair the operation of the dump valve and Automatic Section
Control (ASC).
a) Select ‘Raven’
b) Enter the settings for the Raven Fast Flow regulator valve as displayed in Figure 33.
c) Select the option ‘Close Valve When Flow OFF’.
Note: When using a Raven regulator that operates as a ‘Dump Valve’ then select the option
‘Close Valve When Flow OFF’.
Failure to do this could dead end the system and cause damage to pumps, hoses etc.
See Service Bulletin Section 22, if a positive displacement (piston or diaphragm) pump and a
Raven Fast Flow regulator valve is fitted. KEE recommends a Pressure Relief kit (part number
495181) be fitted to the sprayer. If the kit is fitted then follow the settings as recommended
in the Service Bulletin.
RReevveerrssee
VVaallvvee
DDiirreeccttiioonn
All regulator valves have a two wire control system. Polarity is reversed to change the
direction of the regulator when in use.
Select this option if the valve is turning in the wrong direction i.e. pressure is being increased
when the decrease button is selected on the ‘ZYNX Working’ screen.
CClloossee
VVaallvvee
WWhheenn
FFllooww
OOFFFF
Select this option if using a 3 way regulator valve, which also operates as a ‘Dump Valve’, such
as the Raven ‘Fast Valve’.
Also select this option if Anhydrous Gas is being used through the regulator.
SSeennssiittiivviittyy
The ‘Sensitivity’ setting refers to the Flowmeter signal, and may need to be set to ‘Reduced’
to stop ‘hunting’. This setting will also make the response to rate changes sluggish.
It is recommended to select ‘Standard’.
Page 55
V1.98 21/06/06
Figure 33: Settings for Common Regulator Valves
Controller Max On Time Min On Time
PWM
Setting
Gain Setting
20 sec. or higher
Reg Valve
Eg. KEE KZCO
Standard 4.0 sec. 8 msec. 100% 16ms/%
16 sec Reg Valve
Eg. Arag Yellow Band
Standard 4.0 sec. 8 msec. 100% 16ms/%
Hardi Reg. Valve
Standard 4.0 sec. 8 msec. 100% 16ms/%
Raven STD Reg.
Valve
Standard 4.0 sec 8 msec. 100% 16ms/%
6 sec Reg. Valve
Eg. Arag Grey Band
Standard 2.0 sec. 2 msec. 100% 16ms/%
Raven Fast Flow
Reg. Valve (1.5 sec.)
Raven 40 msec. 8 msec 100% 2.4 ms/%