Topcom X20 Paint Sprayer User Manual


 
Setup Options- Tanks
6.2 Proportional Valve Settings
Spraying systems that use a proportional valve are controlling a hydraulic valve, which in turn
drives a hydraulic motor which drives a pump. Spray regulation is controlled by changing the
pump speed. The settings will need to be tuned for the sprayer.
Select ‘Prop. Valve’ in the ‘Controller’ window.
Select ‘Settings’, this will then open up the window to allow the operator to alter the settings
for the proportional valve for the tank selected.
VVaallvvee
OOppttiioonnss
HHiigghh
MMiinniimmuumm
PPWWMM
RRaannggee
Deselecting the ‘High Minimum PWM Range’ option (default) displays the ‘Min PWM’ range
values between 5% and 40%.
Selecting the ‘High Minimum PWM Range’ option displays the ‘Min PWM’ range values from
42.5% to 60%.
AAdddd
DDiitthheerr
Select ‘Add Dither’ when using Proportional Valves.
EEnnaabbllee
SSoofftt
SSttaarrtt
The option ‘Enable Soft Startup’ should be left unselected.
CClloossee
VVaallvvee
WWhheenn
FFllooww
OOfff
f
The option ‘Close Valve When Flow Off’ should be left unselected.
Page 56
V1.98 21/06/06
FFiigguurree
3344::
PPrrooppoorrttiioonnaall
VVaallvvee
SSeettttiinnggss
ppaaggee