Topcom X20 Paint Sprayer User Manual


 
Setting Up -Area/Volume
If only one tank is selected then the Sub-Area/Volume readouts are for ‘Tank 1’. If more than
one tank is selected, then the operator can select to display the Sub Area/Volume readouts for
each tank. When more than one tank is selected then arrows appear next to the ‘Tank
Number’, the arrows are used to select a tank number. The Sub Area/Volume readouts will
display the area covered and volume used for each tank, on both the ‘Working Screen’ and
AREA window readouts. As the arrows are used to select the Tank number you will notice the
‘Tank Indicator’ on the ‘Working Screen’ will change to show which ‘Tank’ the Sub
Area/Volume readouts are displaying.
The ‘Tank Indicators’ can also be changed from the ‘Working Screen’ by repeatedly selecting
either the ‘Sub-Area’ or ‘Sub-Volume’ readouts, the orange ‘Tank Indicator’ will indicate
which ‘Tank’ the readouts are displaying for. The orange ‘Tank Indicators’ are aligned in the
same position as the Tank (1,2 or 3) Icons.
Reset Area Number- The Reset Area Number button resets the both the sub-area and sub-
volume with one action, for the Sub Area Number displayed.
TIME- The ‘TIME’ window displays the accumulated spraying time while the Master is ON. By
selecting the ‘RESET’ button the spraying time can be reset; a window is displayed warning
the operator, select ‘YES’ to reset or ‘NO’ to cancel.
Page 87
V1.98 21/06/06