Toshiba STE 58760 Welding System User Manual


 
STE 58760
2-4
(4) The contents of the system disk are read in by the controller.
The LED on the FDD blinks several times and the contents of the floppy disk are read to the
controller. When the controller is correctly started up, the following message appears on the
LCD screen on the teach pendant.
>
EDIT LOAD SAVE TESTRUN> RESET NEXT
F1 F2 F3 F4 F5 F6
When the cold start operation is conducted, the controller works as follows.
When the power is turned on, the controller reads in the system programs from the system disk.
While the system programs are read, the lamp on the "START" switch blinks. When the system
programs have been read in from the disk, the lamps on the "START", "STOP" and "CYCLE
STOP" switches light up for 0.5 sec. After that, the lamp on the "STOP" switch lights up and
the screen as shown above appears. After that, files of parameters and so forth are read to
the controller. After all the required files are read to the controller, the contents in the
automatic execution file are executed. In this state, the controller can be operated.
For details of the automatic execution file, see 3.5, "Batch Process".
When an error occurs during the cold start operation, take proper action corresponding to the
error message appearing on the screen.
(5) After the controller has been started up, remove the system disk from the FDD. When
pressing the FDD pushbutton, the floppy disk is slightly ejected from the disk entrance.
Hold the label portion of the disk and remove the disk.