STE 58760
3-22
(Name)
Specifies the name of device to be connected. The name of the device is specified with one of
the following abbreviations. If it is not specified, the abbreviation of the communication
channel is specified.
Printer ... "PRT"
Host computer ... "HOST"
Communication channel 1 (default) ... '"COM1"
Communication channel 2 ... "COM2"
Communication channel 3 ... "COM3"
The name "HOST" can be used only for one communication channel.
(Spare)
This data should be always set to "0".
(Procedure)
When "HOST" is specified for (name), specify the procedure used for data communication.
For details, see the Communication Manual.
No procedure ... 0
Simple procedure (presence of check sum) ... 1
Simple procedure (absence of check sum) ... 2
Unless (name) is "HOST", data communication is done without any procedure.
(Rate)
Specifies the rate of data communication. Select one of the following rates.
9600 bps ... 9600
4800 bps ... 4800
2400 bps ... 2400
1200 bps ... 1200
(Character length)
Specifies the character length for communication.
8 bits .8
7 bits .7