Toshiba STE 58760 Welding System User Manual


 
STE 58760
3-27
(Example)
File selection numbers when using 6 signal points (extending from signal points 10 to 15) are as
follows:
Input signal File selection number
15 14 13 12 11 10 Binary Decimal
OFF OFF OFF OFF OFF OFF 000000 0
OFF OFF OFF OFF OFF ON 000001 1
OFF OFF OFF OFF ON OFF 000010 2
・・
・・
・・
・・
・・
・・
・・・・・・
OFF ON OFF ON OFF ON 010101 21
・・
・・
・・
・・
・・
・・
・・・・・・
ON OFF ON OFF ON OFF 101010 42
・・
・・
・・
・・
・・
・・
・・・・・・
ON ON ON ON ON OFF 111110 62
ON ON ON ON ON ON 111111 63
3.4.2 Contents of File
The names of files written in robot language are registered on one line at a time in the external
selection file. Each file name corresponds with the file selection number, which is determined
by subtracting a 1 from the number on which the file is registered. The file on line 1 accords
with the file selection number 0; the file on line 2 accords with the file selection number 1; and
so on. The number of characters per line should be 12 characters. For an example of how to
create a robot language program file, see Chapter 4, "Example of Simple Operation
For a detailed description, see the Operating Manual. For details on robot language, see the
Robot Language Manual.
The following are examples of external selection files.
MAIN0. SRC
MAIN1. SRC
MAIN2. SRC
MAIN3. SRC
MAIN4. SRC
MAIN5. SRC
MAIN6. SRC
MAIN7. SRC
12 characters