Custom Section Mapping
As the current Sprayer Switchbox has only 6 switches
available, and the Spray ECU can control up to 30 sections.
Custom Section Mapping provides a method of operating
several sections from each switch.
Specific requirements will vary between operators and this
window allows the operator to set which section switches
operate which section valves.
The example (Figure 8-10) shows a 14 section dual line system
with section 15 controlling the second line. Sections 1, 2 and
3 are operated by Switch 1, sections 4,5 and 6 are operated by
Switch 2 etc, with the second line being controlled from switch
6 through the control circuit for section 1.
By touching the screen put an ‘X’ in the box (touching the
same box again will remove the ‘X’ from the box).
Figure 8-10. Custom Section Mapping