The ASC option in Guidance General Setup must also be selected
(see X20 Guidance manual Page 4-21 Chapter 4).
Select Off (Figure 8-1 on page 8-1) if Guidance is not working.
Variable Rate Control (VRC)/Logging Mode
If you are not using VRC or Logging select Off (Figure 8-1 on
page 8-1).
Select Logging Only if you are not using a VRC prescription
map but are logging the Spray Rate’s elevation mapping, using the
Maplink VRC software. This allows logging to be done without
loading a VRC prescription map.
Select VRC and Logging if using the Maplink VRC software,
to load a VRC prescription map to control the Spray Rate to a
region based map. A VRC Master button will be displayed on the
Guidance and Maplink VRC screens.
The only difference between Logging Only and VRC and Logging,
is when Logging Only is selected, the VRC Master button is
removed from the Guidance screen, to prevent confusion.
(VRC)/Logging Synchronization
When Logging Only and VRC and Logging are selected, then the
VRC/Logging Synchronization window will be displayed.
When selecting Logging Only and VRC and Logging,
Variable Rate Control (Maplink VRC) must be
selected in the Product Selection screen during
startup.