Select 3. Enter to accept and save the factor.
The current calibration factor is displayed and the current
units are displayed in blue.
Minimum Flow
Select the 1. calculator icon
Enter the minimum flow of the Flow Meter fitted to the 2.
Sprayer
Every Flow Meter has a minimum value. Below this point,
it can not control accurately. Therefore when the Flow
Meter reaches this value, the Regulator Valve will not
attempt to control below this minimum value, it will hold
the Regulator Valve at that point. Then the Flow readout
will display a red indicator alerting the operator of this.
Selecting the Flow readout (button) displays an explanation
of the red indicator, as the red indicator can mean
Minimum Flow (Flow Meter) or Minimum Nozzle Flow.
If typing a Flow Sensor Calibration for a Raven
Flow Sensor then you must divide the factor by 10
before entering the factor. This is because the Raven
console does not have decimal points and assumes
the last digit is a decimal place.
For example: If the Raven label says ‘187’, then you
should enter 18.7 as the calibration factor.
NOTICE
NOTICE