Topcon A2677 Paint Sprayer User Manual


 
8-38
www.topconpa.com
X20 Sprayer Reference Manual
Type
• 5 Bar—select this if using the standard TPA Pressure Sensor
10 Bar—select this if a 10 Bar Pressure Sensor is fitted.
See “Calibrating the Pressure Sensor”, page 10-3.
Input Gain
x1—select this (default) if the Spray Interface controller was
purchased after July 2005
x2—select this if the Spray Interface controller was
purchased before July 2005.
Please note: When the Spray ECU is selected Input Gain is not
required.
Flow
This factor may be entered manually into the Flow Sensor
Specifications window. Make sure the units (volume), selected
from the Units page (page 8-38), corresponds to the units used on
the Flow Sensor.
If the Flow Meter calibration is not known or the operator wants
to check the Calibration Factor, return to the Working screen, see
“Calibrating the Flow Meter”, page 10-13.
Most Flow Sensors have a calibration factor stamped
or labeled on the Flow Sensor body. The factor will
be in pulses per volume, (volume can be Litres, US
Gallons etc).