Topcon A2677 Paint Sprayer User Manual


 
5-6
www.topconpa.com
X20 Sprayer Reference Manual
Please note: As a general rule the CONNECTOR 2 plug is
only required if the Sprayer:
Has more than 10 Boom Sections
Has more than 2 tanks
Is connecting to external switches which control the
Boom Sections (boom sensing), eg: Boom Section
switches on a T Bar or Joy Stick or other third party
section switches.
Connector 3
Normally CONNECTOR 3 (16 pin) is only required if the
Sprayer requires extra pressure inputs, tank level sensors and
extra encoder inputs.
3-Pin Weather Pack Connector/Ground Speed
The Tractor Harness has a 3-Pin Weather Pack connector
labelled ‘Ground Speed’.
Either an A328 Shaft/Speed Sensor Kit or A449 Radar Sensor
Interface Harness (not included in this kit) can be connected
to this connector.
Typically, the Radar Sensor Interface Harness would be
connected to the Tractor Harness Ground Speed Connector.
See "Connecting to a Speed Sensor", page 5-11 for installing
the Shaft/Speed Sensor Kit or Radar Interface Kit.
NOTICE
Only one speed connector can be used at any one
time.
NOTICE