Topcon A2677 Paint Sprayer User Manual


 
6-8
www.topconpa.com
X20 Sprayer Reference Manual
Please note: When using Automatic Section Control (ASC), when
the sections are switched OFF, the Boom Sections and the Spray
Indicators turn grey; when the sections are switched ON, under ASC
the Boom Sections and Spray Indicators turn green.
Spraying Indicators— are displayed below the Boom Sections
On the Sprayer Working screen (Figure 6-7 on page 6-6) there
are 16 Spraying Indicators, because there are 16 section valves
in total (8 front Section Valves and 8 back Section Valves). The
8 Spraying Indicators on the left represent the Boom Sections on
the front line, the 8 Spraying Indicators on the right represent the
Boom Sections on the back line.
Table 6-1 on page 6-7 displays and explains the different states
of the Spraying Indicators. Table 6-2 shows what different color
Spraying Indicators indicate about their status.
Auto—when selected (by selecting Auto on the Switchbox
or Sprayer Working screen) the AUTO button will become
highlighted and a green indicator will be shown in the AUTO
button
When AUTO is selected the Spray Controller automatically
adjusts the flow, according to speed, width or number of sections
that are ON..
Spraying Indicators Color Indicators
Spraying
Indicator
Meaning
Boom Section is not spraying.
Boom Sections is spraying.
Table 6-2. Spraying Indicators Color Indicators