Topcon A2677 Paint Sprayer User Manual


 
18-9
A2677 Rev 1.5
X20 Sprayer Reference Manual
Control
Problem
Will not control in Auto
Causes Solutions Tips
22. Regulator Valve
is operating wrong
way
Select Reverse Valve
Direction
Pressure should go
up when the Up
arrow is pressed in
Manual
Volumes
Problem
Incorrect volumes
Causes Solutions Tips Additional Data
23. Flow Meter
calibration is
incorrect
Perform FCAL
procedure
Performing the
FCAL
procedure takes
into account
wear, plumbing
etc. The FCAL
supplied with
the Flow Meter
is valid when
new and the
plumbing is as
specied as the
manufacturer
Yes, see
Additional
Data, Problem
23, page 18-16.
24. Volume
reference is
inaccurate
Measure the
volume of liq-
uid placed into
tank, or use
volume after
calibration of
Flow Meter as
reference
Tank markings
are very
inaccurate and
change over
time
Yes, see
Additional
Data, Problem
24, page 18-17.