Problem
Nozzles losing pattern when slowing down
Causes Solutions Tips Additional Data
25. Pressure
dropping too
low when at
low speeds
Change nozzles
to give better
range, set the
low pressure
hold to hold
pressure at
minimum for
nozzles
There are 3
minimum hold
settings: Nozzle,
Flow Meter and
Speed. When
activated, the
Sprayer
switches to
Manual and
holds the
regulator at that
point
Yes, see
Additional
Data, Problem
25, page 18-18.
Alarms
Problem
Alarm keeps sounding
Causes Solutions Tips Additional Data
26. A problem
has developed
that triggers the
alarm
Fix the
problem that
has caused the
alarm to sound
There is a wide
variety of alarms
associated with
the Sprayer,
some are
critical, others
are warnings
only. See the
associated text
for the alarm
types and
suggested
settings
Yes, see
Additional
Data, Problem
26, page 18-19.