12-6
www.topconpa.com
X20 Sprayer Reference Manual
• 5 Volts between Pin-A and Pin-B
Sensor connected but not exposed to the magnet: 3.
• 11-12 Volts between Pin-B and Pin-C
• 5 Volts between Pin-A and Pin-B
Sensor connected with exposure to the magnet: 4.
• 11-12 Volts between Pin-B and Pin-C
• 0 Volts between Pin-A and Pin-B
WARNING
Sensor power is 1 Amp current limited and should
never be limited for any other purpose.
WARNING