Topcon A2677 Paint Sprayer User Manual


 
8-15
A2677 Rev 1.5
X20 Sprayer Reference Manual
Pressure (Pr) Sense
The Spray Rate Controller can monitor the pressure in a spray
system, which is displayed as a Pressure readout on the Working
screen (Figure 6-7 on page 6-7). The Spray Rate Controller uses
Flow to control.
Low and high pressure alarms can be set, to alert the operator
when the pressure in the system goes above the high alarm point or
below the low alarm point, see “Alarms”, 8-57.
Select Tank 1 if an electronic Pressure Sensor is fitted to the
Sprayer, otherwise leave deselected. See page 8-38 or 8-42 (for
Spray ECU configuration) to select the type of electronic Pressure
Sensor fitted to the system.
If more than 1 tank was selected in the Tanks window then a
Pressure Sensor can be selected for each tank that has a Pressure
Sensor present.