Topcon A2677 Paint Sprayer User Manual


 
8-19
A2677 Rev 1.5
X20 Sprayer Reference Manual
Settings for Raven Controller Mode
Controller Max On Time PWM Setting Min On Time Gain Setting
Raven
Fast Flow
Reg valve
(1.5 sec.)
Raven 40 msec. 100% 8 msec. 2.4ms/%
Table 8-2. Settings for Raven Controller Mode
CAUTION
When using a Raven Regulator that operates as
a Dump Valve then you must select the Close
Valve When Flow Off option. Failure to do this
could dead end the system and cause damage to
pumps, hoses etc.
See "Service Bulletins", Chapter 7 if a positive
displacement (piston or diaphragm) pump and a
Raven Fast Flow Regulator Valve are fitted.
TPA recommends a Pressure Relief kit (495181)
to be fitted to the Sprayer. If the kit is fitted then
follow the settings recommended in the Service
Bulletin.
CAUTION