Topcon A2677 Paint Sprayer User Manual


 
10-18
www.topconpa.com
X20 Sprayer Reference Manual
Select the Boom Section that has been disconnected from the 5.
valve and is now supplying the measuring container
The section should turn green on the screen (Figure 10-6 on
page 10-17)
Select the Tank icon on the screen you are calibrating 6.
Select 7. CAL X (X is the tank number)
A Calibrate Tank window appears on the right of the screen
Start the pump and select 8. Flow On/Off
The Valve and the Master will turn on, and liquid will flow
into the measuring container.
The pulse readout next to the flow button should increment
Press 9. Flow On/Off when there is approximately 20 liters in
the measuring container
Measure this volume as accurately as possible and enter this 10.
volume into the appropriate section of the window
The system will calculate the correct Flow Calibration Factor
and register this into the system.
Press 11. Reset
Repeat the procedure if required 12.
Select 13. DONE when finished.