X20 Sprayer Reference Manual
Part No. Usage
A2266
Use if connecting to a 2-wire dump valve and 12V
is applied to the dump valve when the Master switch
is OFF
A2267
Use if connecting to a Solenoid Valve, with 6mm
spade terminals and 12V is applied to the dump
valve when the Master switch is OFF
A2268 Use if connecting to a 3-Wire Dump Valve and 12V
is applied to the Dump Valve when the Master is
OFF
A2269
Use when connecting to a 3-Wire Dump Valve and
12V is applied to the Dump Valve when the Master
is ON
Choosing the Correct Adaptor for the Dump Valve
Figure 5-1. How to Choose the Correct Adaptor for the
Dump Valve
When all the Arag connectors are in place, tighten the 2.
screw at the top of the Arag connector, using a screwdriver,
to secure the connector to the Section and Dump Valves
Tidy any excess harness, using cable ties3.
To complete the installation go to page 5-31, to connect the
Spray ECU Power/Comms Harness to the battery.