X20 Sprayer Reference Manual
Installing the Spray ECU 30S Kits to an Existing
Topcon Precision Agriculture Controller
This section is for users who are replacing an existing Topcon
Precision Agriculture (I.E. KEE) MK3, MK5 Sprayer console or Spray
Rate Interface.
Before Removing the Existing Controller
Ensure that the system is functioning correctly 1.
Run the Sprayer and record the minimum and maximum 2.
pressure and flow rates attainable
Record all of the calibration factors 3.
Record all of the section width values.4.
Removing the Existing Controller
Remove the existing TPA Spray Rate Controller console or 1.
TPA Spray Rate Interface
Remove the existing Tractor Harness. 2.
Installing the Spray ECU 30S Kits
Connect the Tractor Harness to 1. Connector 1 on the Spray
ECU (Figure 5-11 on page 5-30)
The Tractor Adaptor Harness connects to the Spray ECU
and runs the Harness as far as the drawBar of the tractor or
vehicle, where a breakaway is attached so the vehicle can be
easily detached from the trailing Sprayer.