Topcon A2677 Paint Sprayer User Manual


 
5-9
A2677 Rev 1.5
X20 Sprayer Reference Manual
Please note: The Sprayer Harness may have other connectors,
refer to the Sprayer Installation kit that came with your Sprayer
kit for more information.
The Dump Valve connector may be located on the Sprayer
Harness. If the Valve Harness has an Arag Interface box
incorporated into the Valve Harness, then the Dump Valve
connector will be located on the Valve Harness.
Figure 5-4. 3-Pin Weather Pack Sensor
TIP
For testing purposes on all 3-Pin sensor connectors
(Shaft/Speed Sensor and Flow Meter) the voltage on
each pin should be:
Pin A: +% VDC Signal
Pin B: Ground
Pin C: +12VDC Sensor Power
See Figure 5-4.
TIP