Lincoln Electric SVM133-B Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-76 F-76
COMMANDER 400
This is the typical DC open circuit
output voltage generated from a
properly operating machine. Note
that each vertical division represents
20 volts and that each horizontal
division represents 5 milliseconds in
time.
Note: Scope probes connected at
“WIRE” welding output terminals.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (WIRE CV TAP)
MAX CONTROL POT HIGH IDLE NO LOAD
0 volts