Lincoln Electric SVM133-B Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-117 F-117
COMMANDER 400
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics. OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
Mode No Load RPM Load RPM
Low Idle 1325 - 1400 NA
High Idle 1890 - 1915 1800
WELDER DC (STICK) OUTPUT
Range Switch Fine Control Open Circuit Load Volts Load Amps
Volts
Maximum Maximum 70 40 500
WELDER CV (WIRE) OUTPUT
Range Switch Fine Control Open Circuit Load Volts Load Amps
Volts
Maximum Maximum 48 40 500
AUXILIARY POWER OUTPUT
230 Volt Receptacle 115 Volt Receptacle
Open Circuit Load Volts Load Amps Open Circuit Load Volts Load Amps
Voltage Voltage
230 - 250 224 44.6 115 - 132 108 - 126 13 - 16