Lincoln Electric SVM133-B Welder User Manual


 
WIRE FEED (CONSTANT VOLTAGE)
WELDING
Stick and Wire models only. Connect a wire feeder to
the Commander 400 (see the Accessories section)
and set the welder controls according to the instruc-
tions in “Controls and Settings” in this section of the
manual.
The Stick and Wire model of the Commander 400, with
its CV tap, permits it to be used with a broad range of
flux cored wire (inner shield and Outer shield) elec-
trodes and solid wires for MIG (GMAW).
For any electrodes, the procedures should be kept
within the rating of this machine. For additional elec-
trode information, see Lincoln publications N-675, GS-
100 and GS-210.
AUXILIARY POWER
Be sure that any electrical equipment plugged into the
generator AC power receptacles can withstand a ±10%
voltage and a ±3% frequency variation.
The Commander 400 can produce 10,000 watts of 60
Hz, single-phase auxiliary power. (The rating in watts
is equivalent to volt-amperes at unity power factor.)
The output voltage is within ±10% at all loads up to the
rated capacity.
The following receptacles are provided:
• Two 15 amp-120VAC duplex FGCI receptacles
(5-15R)
• One 50 amp-120/240VAC receptacle (14-50R)
The 50 amp receptacle has a maximum permissible
output of 44 amps. However, it can be split to power
two separate, single-phase 120VAC branch circuits
each capable of 44 amps output.
NOTE: The two 120VAC outlets of the 120/240VAC
receptacle cannot be paralleled. They are on two dif-
ferent phases.
The auxiliary power receptacles should be used with
only three-wire, grounded type plugs or approved dou-
ble-insulated tools with two-wire plugs. The current rat-
ing of any plug used with the system must be at least
equal to the current-carrying capacity of the associated
receptacle. An optional power plug kit is available.
See the Accessories section.
SIMULTANEOUS WELDING AND AUXIL-
IARY POWER LOADS
The auxiliary power ratings above are with no welding
load. Simultaneous welding and power loads are spec-
ified in Table B.4. The permissible currents shown
assume that current is being drawn from either the 120
VAC or 240 VAC supply (not both at the same time).
OPERATION
B-12 B-12
COMMANDER 400
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
WARNING
Welding
Output Range
Setting
50-575
400
270
230
180
120
90
Welding Output
500A/40V
400A/36V
270A/31V
230A/29V
180A/27V
120A/25V
90A/24V
Permissible
Power - Watts
(Unity Power
Factor)
None
None
3000
6000
7500
9500
9500
@120 V ±10% *
0
0
28
56**
70**
88**
88**
@ 240 V ±10%
0
0
14
28
35
44
44
* Each GFCI duplex receptacle is limited to 15 amps.
** Not to exceed 44 A per 120 VAC branch circuit when splitting the 240 VAC output.
TABLE B.4 Commander 400 Simultaneous Welding and Power Loads
Permissible Auxiliary
Current in Amperes