D-Link dgs-3420 Work Light User Manual


 
xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
170
<int 1-8191> - Enter the remote MEP ID used here. This value must be between 1 and 8191.
action - Specifies to start or to stop the management lock function.
start - Specifies to start the management lock function.
stop - Specifies to stop the management lock function.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To start management lock:
DGS-3420-28SC:admin# cfm lock md op-domain ma op-ma mepid 1 remote_mepid 2
action start
Command: cfm lock md op-domain ma op-ma mepid 1 remote_mepid 2 action start
Success.
DGS-3420-28SC:admin#
14-18 cfm loopback
Description
This command is used to start a CFM loopback test. Press Ctrl+C to exit the loopback test. The
MAC address represents the destination MEP or MIP that can be reached by this MAC address.
The MEP represents the source MEP to initiate the loopback message.
Format
cfm loopback <macaddr> [mepname <string 32> | mepid <int 1-8191> md [<string 22> |
md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]] {num <int
1-65535> | [length <int 0-1500> | pattern <string 1500>] | pdu_priority <int 0-7>}
Parameters
<macaddr> - Specify the destination MAC address.
mepname
- Specify the MEP name.
<string 32> - Specify the MEP name. The maximum length is 32 characters.
mepid - (Optional) Specify the MEPID.
<int 1-8191> - Specify the MEP MEPID between 1 and 8191.
md - (Optional) Specify the maintenance domain name.
<string 22> - Specify the maintenance domain name. The maximum length is 22
characters.
md_index Specifies the MD index value used.
<uint 1-4294967295> - Enter the MD index value used here. This value must be between
1 and 4294967295.
ma - (Optional) Specify the maintenance association name.
<string 22> - Specify the maintenance association name. The maximum length is 22
characters.
ma_index Specifies the MA index value used.
<uint 1-4294967295> - Enter the MA index value used here. This value must be between
1 and 4294967295.
num - (Optional) Specify the number of LBMs to be sent. The default value is 4.