89-7 config dst
Description
This command is used to change Daylight Saving Time settings.
Format
config dst [disable | repeating {s_week <start_week 1-4,last> | s_day <start_day sun-sat> |
s_mth <start_mth 1-12> | s_time <start_time hh:mm> | e_week <end_week 1-4, last> | e_day
<end_day sun-sat> | e_mth <end_mth 1-12> | e_time <end_time hh:mm> | offset [30 | 60 | 90
| 120]} (9) | annual {s_date <start_date 1-31> | s_mth <start_mth 1-12> | s_time <start_time
hh:mm> | e_date <end_date 1-31> | e_mth <end_mth 1-12> | e_time <end_time hh:mm> |
offset [30 | 60 | 90 | 120]} (7) ]
Parameters
disable - Disable the DST of the switch.
repeating - Set the DST to repeating mode.
s_week - Configure the start week number of DST.
<start_week 1-4,last> - Configure the start week number of DST. The values are 1 to 4.
s_day - Configure the start day number of DST.
<start_day sun-sat> - Configure the start day number of DST. The values are sun, mon, tue,
wed, thu, fri and sat.
s_mth - Configure the start month number of DST.
<start_mth 1-12> - Configure the start month number of DST. The values are 1 to 12.
s_time - Configure the start time of DST.
<start_time hh:mm> - Configure the start time in hh:mm of DST.
e_week - Configure the end week number of DST.
<end_week 1-4,last>
- Configure the end week number of DST. The values are 1 to 4.
e_day - Configure the end day number of DST.
<end_day sun-sat> - Configure the end day number of DST. The values are sun, mon, tue,
wed, thu, fri and sat.
e_mth - (Optional) Configure the end month number of DST.
<end_mth 1-12>
- Configure the end month number of DST. The values are 1 to 12.
e_time - Configure the end time of DST.
<end_time hh:mm> - Configure the end time in hh:mm of DST.
offset - Specify the number of minutes to add or to subtract during summertime. The range of
offsets are 30, 60, 90, and 120. The default value is 60.
30 - Specify 30 minutes to add or to subtract during summertime.
60 - Specify 60 minutes to add or to subtract during summertime.
90 - Specify 90 minutes to add or to subtract during summertime.
120 - Specify 120 minutes to add or to subtract during summertime.
annual - Set the DST to annual mode.
s_date - Configure the start date number of DST.
<start_date 1-31> - Configure the start date number of DST. The values are 1 to 31.
s_mth - Configure the start month number of DST.
<start_mth 1-12> - Configure the start month number of DST. The values are 1 to 12.
s_time - Configure the start time of DST.
<start_time hh:mm> - Configure the start time in hh:mm of DST.
e_date - Configure the end date number of DST.
<end_date 1-31> - Configure the end date number of DST. The values are 1 to 31.
e_mth - Configure the end month number of DST.