Lincoln Electric SVM135-B Welder User Manual


 
F-79
TROUBLESHOOTING AND REPAIR
F-79
AUXILIARY TRANSFORMER NO. 1 REMOVAL AND
REPLACEMENT PROCEDURE
Service and repair should only be performed by Lincoln Electric factory trained
personnel. Unauthorized repairs performed on this equipment may result in dan-
ger to the technician or machine operator and will invalidate your factory warran-
ty. For your safety and to avoid electrical shock, please observe all safety notes
and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to per-
form the test/repairs safely, contact the Lincoln Electric service department for
technical troubleshooting assistance before you proceed. Call 216-383-2531 or
1-800-833-9353(WELD).
------------------------------------------------------------------------------------------------
DESCRIPTION
This procedure will aid the technician in the removal and replacement of auxiliary
transformer No. 1.
This procedure takes approximately 25 minutes to perform.
MATERIALS NEEDED
3/8 in. nutdriver
Wire cutters
Wire splicer or soldering equipment
POWER WAVE 455/POWER FEED 10
WARNING
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC