Lincoln Electric SVM135-B Welder User Manual


 
C-13
ACCESSORIES
C-13
Installation is as follows:
1. Turn off power.
2. Remove the two screws from the front of the
blank option panel at the location you choose to
install your new option (bottom) of the Control
Box cabinet. Save the screws, discard the old
panel or save for future use.
3. Tilt the new option panel away from the front
opening of the Control Box cabinet. Plug the
electrical connector into the proper connector on
the right side of the main printed circuit board
(12 pin). Make sure the connector latches in
place.
4. Position the new panel, taking care not to dam-
age the connections and the printed circuit board
on the back.
5. Align the screw holes, replace the two screws
and tighten.
K1542-9 DUAL PROCEDURE/MEMORY PANEL
(SMALL PANEL)
The Dual Procedure/Memory panel provides for the
selection of either of two procedures, or a gun switch
for remote selection of the procedure. In addition,
there are six permanent memory storage locations
for saving commonly used procedures. Procedures A
and B are “soft” type memories that record any
changes made to them. The six memory locations
are “hard” or more permanent type memories. Any
changes made must be consciously saved back to
them. Furthermore, each memory contains only one
procedure, therefore any combination of memories
may be recalled to procedure A and B.
Descriptions
Indicator Lights - Red LED’s indicate the procedure
and active memory and save mode if applicable.
Dual Procedure Selection
The procedure switch is used to scroll the indicator to
select PROCEDURE A, PROCEDURE B, or the
GUN switch. When the GUN switch is selected, the
procedure is determined by the position of the switch
located at the gun. Under this condition, indicators
will show that the gun switch has been selected and
also which procedure the gun switch is requesting.
Memory Selection
RECALL - When a memory key is depressed, its indi-
cator comes on and its contents are copied to the
active procedure. As long as no changes are made
to the contents of that procedure, the memory indica-
tor will be on any time that procedure is active. This
indicates that their contents are the same. Any
change to that procedure will cause the memory indi-
cator to go off, indicating that they are no longer
equal.
SAVE - The save mode allows “hard” memories to be
changed. Pressing the SAVE key will light the save
indicator, and enter the save mode. In the save
mode, the indicator for the memory that was the
source of the active procedure’s contents will blink,
whether their contents are still equal or not. This fea-
ture allows the user to choose to save an active pro-
cedure back to its source, or some other location.
To complete the save transaction requires the selec-
tion of one of the memory keys. When the memory
key is pressed in the save mode, it’s contents are
overwritten with the contents of the active procedure.
This means that the contents of the memory location
and the active procedure are now equal, and thereo-
re, by definition, each of their indicators will be lit,
and the save mode will be exited. To exit the save
mode without saving, depress the save key a second
time. This feature allows the operator to determine
the source of the active procedure’s contents without
actually overwriting it.
POWER WAVE 455/POWER FEED 10
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC