Chassis Fault Management
Chassis Fault Management WindowDetailed Description
The Chassis Fault Management window displays four tabs: General, Power Supply, Temperature, and
Fan.
General Tab
The General tab (see Figure 4-10 on page 4-21) displays three areas: Chassis Availability, LED Status,
and Cisco Contact Details.
Chassis Availability
The Chassis Availability area contains attributes that reflect the availability of the chassis, as follows:
Up TimeDisplays the up time after the last reset.
Last Changed TimeDisplays the time the chassis hardware was last modified.
Note Software and configuration changes through IOS CLI & SNMP are detected by SYSLOG and
ConfigManEvent traps (see Chapter 18, Fault Management, for further information) and the Event
Command History Table that can be launched from the Chassis.
Last Restart ReasonDisplays the reason for the last restart.
Last Authentication Failure AddressDisplays the last authorization failure IP address for the selected
chassis. The Last Authentication Failure Address field refers to the fact that the SNMP agent on the
Cisco 12000/10720 Router has received a protocol message that is not properly authenticated. The IP
address is the source of the message. This is a security issue which should be investigated.
Clock Source StatusNot applicable to Cisco 12000/10720 Router Manager.
LED Status
The LED Status area is not applicable to Cisco 12000/10720 Router Manager.
Cisco Contact Details
The Cisco Contact Details area displays any provided Cisco contact details.
Power Supply Tab
The Power Supply tab (see Figure 4-11 on page 4-22) displays two areas: Power Supply and Voltage.
Power Supply
The Power Supply area displays the following information for each power supply (in tabular format):
DescriptionTextual information for the power supply.
StateCurrent state of the power supply. Possible state values can be Normal, Warning, Critical,
Shutdown or Not Present.
SourcePower supply source. Possible source values are: unknown, ac, dc, external, or internal