APS Interface Configuration
APS Configuration WindowDetailed Description
The APS Configuration window displays a single APS tab.
APS Tab
The APS tab (see Figure 8-7 on page 8-19) displays a single APS Interface area.
APS Interface
The APS Interface area contains the following buttons and fields:
WorkingSelect this button to establish a working interface.
ProtectSelect this button to establish a protected interface.
GroupRepresents the group association of the interfaces. The value of Group ranges from 0 to 255.
AuthenticationAllows you to set values, which serve as check on entry of packets (information) sent
over the network. This shields the system from any damage on account of data download.
Hello TimeSet time for the working interface to report on its status to the protected interface. The
interface is bidirectional by default.
Hold TimeSet the time for protected interface (standby system) to wait for the working interface to
communicate on its status. On expiry of time set, the protected interface takes over as the working or the
active interface.
Revert ModeChoose Revertive to enable automatic switch-over from the protected interface to the
working interface after the working interface becomes available.
Direction ModeChoose the interface direction mode. Options available are:
UnidirectionalPackets are received and transmitted independently.
BidirectionalPackets are transmitted and received in pairs.
Authentication StringSpecifies a string which must be present to accept any packet on the OOB (Out
Of Band) communication channel.
Interconnect IP AddressIP Address of the router that contains the working interface.
LockoutSet the value to yes or no. Yes prevents the working interface from switching to the protected
interface.
Revert TimeSet the revert time, the system reverting automatically to the working interface from
protected interface (standby system) once the working interface is online.
Switch to CircuitSet the value for the circuit to switch to protected interface when working interface