Cisco Systems 12000/10700 V3.1.1 Router User Manual


 
7-16
Cisco 12000/10700 v3.1.1 Router Manager User Guide
OL-4455-01
Chapter 7 Interface Profiles
Creating a POS Interface Profile
EncapsulationAllows you to select HDLC, PPP or FRAME RELAY encapsulation type. The default
value is HDLC.
Cyclic Redundancy CheckAllows you to select an option for cyclic redundancy check. Cyclic
redundancy check basically consists of 16 or 32 bit verification code which has to be same at the both
the transmitting and receiving to ensure the packets sent are received in full without loss of data. By
default it is 32 bit code.
SONET Overhead
The SONET Overhead area allows you to configure the following information:
Path Signal IdentifierAllows you to set the path signal identifier. Permissible values range from 0 to
255.
Section Trace ByteAllows you to set the section trace byte. Permissible values are 0 to 255.
Payload Pointer ByteAllows you to select an option for payload pointer byte from the drop down
menu. Permissible values range from 0 to 3.
Alarm Reporting & Threshold
The Alarm Reporting & Threshold area allows you to configure the following information:
B1 BER Threshold Crossing AlarmAllows you to fix threshold limits for the system to prompt
appropriate B1 BER Threshold alarm messages.
B2 BER Threshold Crossing AlarmAllows you to fix threshold limits for the system to prompt
appropriate B2 BER Threshold alarm messages.
B3 BER Threshold Crossing AlarmAllows you to fix threshold limits for the system to prompt
appropriate B3 BER Threshold alarm messages.
Signal Degrade BERAllows you to fix threshold limits for the system to prompt appropriate Signal
Degrade BER Threshold alarm messages.
Signal Fail BERAllows you to fix threshold limits for the system to prompt appropriate Signal Fail
BER Threshold alarm messages.
Threshold (in 10e-)Displays a threshold value.
Alarm Reporting
The Alarm Reporting area allows you to configure the following information:
Path Remote Defect Indication ErrorsAllows you to enable or disable the path remote defect
indication errors alarm messages.
Line Remote Defect Indication ErrorsAllows you to enable or disable the line remote defect indication
errors alarm messages.
Line Alarm Indication Signal ErrorsAllows you to enable or disable the line alarm indication signal
errors alarm messages.
Receive Data Out of Lock ErrorsAllows you to enable or disable the Receive data output of lock errors
alarm messages.
Path Alarm Indication Signal ErrorsAllows you to enable or disable the path alarm indication signal
errors alarm messages.
Section Loss of Signal ErrorsAllows you to enable or disable the loss of signal errors alarm messages.