Cisco Systems 12000/10700 V3.1.1 Router User Manual


 
18-3
Cisco 12000/10700 v3.1.1 Router Manager User Guide
OL-4455-01
Chapter 18 Fault Management
Cisco 12000/10720 Router Trap Support
Informational
Normal
Chassis Alarms
Table 18-2 provides information on traps that result in alarms raised against the chassis object.
Table 18-2 Monitored Attributes for a GRP Module
Trap Alarm Description Severity Clears
Cold start Cold Start: Agent reinitializing; configuration
may have changed.
Major Cold start
RPR+ Switchover RPR+ Cold Start: Agent reinitializing;
configuration may have changed
Major RPR+ Switchover
RPR Switchover RPR Cold Start: Agent
reinitializing;configuration may have changed
Major RPR Switchover
Redundancy Framework (RF)
Progression
RF Notification: RF state has changed. Active
Unit: <slot-no> State: <RF-state>. Peer Unit:
<slot-no> State: <RF-state>
Major Redundancy
Framework (RF)
Progression
Warm start Warm Start: Agent reinitializing; configuration
is unaltered.
Major Warm start
Authentication Failure Authentication Failure Major Authentication
Failure
Voltage Normal Voltage higher Chassis, normal, <value> mV Normal Normal, Critical,
Shutdown, Warning,
NotPresent
Voltage Warning Voltage higher Chassis, warning, <value> mV Warning Critical, Shutdown,
Warning, NotPresent
Voltage Critical Voltage higher Chassis, critical, <value> mV Critical Critical, Shutdown,
Warning, NotPresent
Voltage Shutdown Voltage higher Chassis, shutdown, <value> mV Critical Critical, Shutdown,
Warning, NotPresent
Voltage Not Present Voltage higher Chassis, notPresent, <value> mV Informational Critical, Shutdown,
Warning, NotPresent
Temperature Normal Slot <no>: Switch Fabric Card Hot Sensor,
normal, <value> degree celsius
Normal Normal, Critical,
Shutdown, Warning,
NotPresent
Temperature Warning Slot <no>: Switch Fabric Card Hot Sensor,
warning, <value> degree celsius
Warning Critical, Shutdown,
Warning, NotPresent
Temperature Critical Slot <no>: Switch Fabric Card Hot Sensor,
critical, <value> degree celsius
Critical Critical, Shutdown,
Warning, NotPresent
Temperature Shutdown Slot <no>: Switch Fabric Card Hot Sensor,
shutdown, <value> degree celsius
Critical Critical, Shutdown,
Warning, NotPresent
Temperature Not Present Slot <no>: Switch Fabric Card Hot Sensor,
notPresent, <value> degree celsius
Informational Critical, Shutdown,
Warning, NotPresent