4. Dedicated Options
4 - 3
No. Abbrev.
Parameter
name
Explanation
SV036 PTYP*
Regenerative
resistor type
F EDCBA98765 4 3 2 10
amp rtyp emgx
bit Explanation
8 Select the regenerative resistor type.
9
Setting Regenerative resistor or regenerative resistor unit
A
rtyp
0 to 1 Setting prohibited
B 2 GZG200W26OHMJ
3 GZG300W20OHMJ
4
MR-RB32 or GZG200W1200HMJ 3 units connected
in parallel
5
MR-RB30 or GZG200W39OHMJ 3 units
connected in parallel
6
MR-RB50 or GZG300W39OHMJ 3 units
connected in parallel
7
MR-RB31 or GZG200W20OHMJ 3 units
connected in parallel
8
MR-RB51 or GZG300W20OHMJ 3 units
connected in parallel
9
MR-RB65 or GRZG400-20HMJ 4 units connected
in serial
A GZG80W26OHMJ
B GZG400W13OHMJ
C GZG400W8OHMJ
D to F Setting prohibited
1.
Only the designated
combination can be used for the regenerative option and
servo drive unit.
There is a risk of fire, so always use the designated combination.
CAUTION
2. Correct protection will not be attained if the parameter setting is incorrect.
Check the regenerative resistor type carefully, and set the parameters.