Mitsubishi Electronics MDS-R Engraver User Manual


 
Appendix 4. EMC Installation Guidelines
A4 - 8
Appendix 4-6 EMC countermeasure parts
Appendix 4-6-1 Shield clamp fitting
The effect can be enhanced by connecting the cable directly to the earthing plate.
Install an earthing plate near each panel's outlet (within 10cm), and press the cable against the earthing
plate with the clamp fitting.
If the cables are thin, several can be bundled and clamped together.
Securely earth the earthing plate with the frame ground. Install directly on the cabinet or connect with an
earthing wire.
Contact Mitsubishi if the earthing plate and clamp fitting set (AERSBAN- SET) is required.
View of clamp section
Outline drawing
Peel the cable sheath at the clamp section.
Cable
Cable
Earthing plate
Earthing plate
Clamp fitting
(Fitting A, B)
Clamp fitting
2-Ø5 hole
Installation hole
[Unit: mm]
Note 1
M4 screw
Shield sheath
(Note 1) Screw hole for wiring to earthing plate in cabinet.
(
Note 2) The earthing plate thickness is 1.6mm.
A B C Enclosed fittings
L
AERSBAN-DSET 100 86 30 Clamp fitting A 2 Clamp fitting A 70
AERSBAN-ESET 70 56 - Clamp fitting B 1 Clamp fitting B 45
CAUTION
Shield of spindle detector cable is not connected to FG (earth). Do not earth the
cable shield with cable clamp, etc.