Mitsubishi Electronics MDS-R Engraver User Manual


 
5. Peripheral Devices
5 - 3
(3) 600V bridge polyethylene insulated wire (IC) 105
o
C product
(Example according to JEAC8001)
Power input
CN30
(L1, L2, L3, )
Regenerative option
CN30
(P, C)
Motor output
CN31LCN31M
(LULVLW )
(MUMVMW )
Control power
(24VDC)
CN22
Magnetic brake
CN9
Terminal
name
Unit type
mm
2
AWG mm
2
AWG mm
2
AWG mm
2
AWG
MDS-R-V1-20 2 14 2 14
MDS-R-V1-40 2 14 2 14
MDS-R-V1-60 2 14 2 14
Servo drive unit
MDS-R-V1-80 2 14
2 14
2 14
1.25 to 2 14 to 16
MDS-R-V2-2020 2 14 2 14
MDS-R-V2-4020 2 14 2 14
MDS-R-V2-4040 2 14 2 14
MDS-R-V2-6040 2 14 2 14
MDS-R-V2-6060 2 14 2 14
MDS-R-V2-8040 2 14 2 14
MDS-R-V2-8060 3.5 12 2 14
Servo drive unit
(2-axis)
MDS-R-V2-8080 3.5 12
2 14
2 14
1.25 to 2 14 to 16
CAUTION
1. Selection conditions follow IEC/EN60204-1, UL508C, JEAC8001.
Ambient temperature is maximum 40°C.
Cable installed on walls without ducts or conduits.
To use the wire under conditions other than above, check the standards you
are supposed to follow.
2. The maximum wiring length to the motor is 30m.
If the wiring distance between the drive unit and motor is 20m or longer, use a
thick wire so that the cable voltage drop is 2% or less.
3. Twist the wire for the regenerative option connection wire.
4. Always wire the grounding wire.