6. Installation
6 - 15
(Example) Drive system
Servomotor
Spindle motor
M
Drive
unit
Sensor
power
supply
Sensor
Instru-
ment
Receiver
<3>
<4>
<5>
<6>
<7>
<8>
<2>
<7>
<2>
<1>
Noise
propagation
path
Measures
When devices such as instrument, receiver or sensor, which handle minute signals
and are easily affected by noise, or the signal wire of these devices, are stored in
the same panel as the drive units and the wiring is close, the device could
malfunction due to airborne propagation of the noise. In this
case,
take the following
measures.
(1) Install devices easily affected as far away from the drive units as possible.
(2) Lay devices easily affected as far away from the signal wire of the drive unit as
possible.
(3) Do not lay the signal wire and power line in parallel or in a bundled state.
(4) Insert a line noise filter on the input/output wire or a radio filter on the input wire
to suppress noise radiated from the wires.
(5) Use a shield wire for the signal wire and power line, or place in separate metal
ducts.
<1> <2> <3>
If the signal wire is laid in parallel to the power line, or if it is bundled
with the power
line, the noise could be propagated to the signal wire and cause malfunction
because of the magnetic induction noise or static induction noise. In this case, take
the following measures.
(1) Install devices easily affected as far away from the drive unit as possible.
(2) Lay devices easily affected as far away from the signal wire of the drive unit as
possible.
(3) Do not lay the signal wire and power line in parallel or in a bundled state.
(4) Use a shield wire for the signal wire and power line, or place in separate metal
ducts.
<4> <5> <6>
If the power supply for the peripheral devices is connected to the power supply in
the same system as the drive units, the
noise generated from the power supply unit
could back-flow over the power line and cause the devices to malfunction. In this
case, take the following measures.
(1)
Install a radio filter onto the drive unit's power supply wire.
(2) Install a power filter onto the drive unit's power supply wire.
<7>
<8>
If a closed loop is created by the peripheral device and drive unit grounding wire, the
noise current could be run through causing the device to malfunction. In this case,
change the device grounding methods and the grounding place.