Mitsubishi Electronics MDS-R Engraver User Manual


 
7. Wiring and Connection
7 - 12
7-6-2 Connection of external regenerative resistor
Connect the regenerative resistor across P-C of CN30.
(1) Connection of one resistor
GZG200W26OHMJ, GZG300W20OHMJ
GZG80W26OHMJ, GZG400W13OHMJ, GZG400W8OHMJ
P
C
Wire length 5m or less
Use a twisted flame retardant wire.
CN30
External optional regenerative resistor
Install a protective cover to prevent foreign matter
(cutting chips, cutting oil, etc.) from entering the
regenerative resistor or the regenerative resistor
from being touched directly.
(2) Connection of three resistors in parallel
GZG200W120OHMJ, GZG200W39OHMJ, GZG300W39OHMJ
GZG200W20OHMJ, GZG300W20OHMJ
100mm or more 100mm or more
P
C
Wire length 5m or less
Use a twisted flame retardant wire.
CN30
External optional regenerative resistor
Install a protective cover to prevent foreign
matter (cutting chips, cutting oil, etc.) from
entering the regenerative resistor or the
regenerative resistor from being touched
directly.