Mitsubishi Electronics MDS-R Engraver User Manual


 
10. Troubleshooting
10 - 20
10-4-3 Parameter No. during initial parameter error
If an initial parameter error (alarm 37) occurs, the alarm and the parameter No. that may be set
incorrectly will appear on the NC Diagnosis screen as shown below. (For M60S, E60 Series NC.)
S02 Initial parameter error 
: Error parameter No.
: Axis name display
If a number larger than the parameter No. is displayed
for the servo drive unit, the alarm is occurring for
several related parameters. Refer to the following table, and correctly set the parameters.
Error
parameter No.
Related
parameter
Details
The CNC setting maxi
mum rapid traverse rate value is
incorrect.
2269 NC setting rapid
The CNC system software may be illegal. Turn the power ON
again.
2271
The CNC setting maximum cutting speed setting value is
incorrect.
The CNC system software may be illegal. Turn the power ON
again.
NC setting clamp
2301 The following settings are overflowing.
Electronic gears
Position loop gain
Speed feedback
SV001, SV002
SV003, SV018
SV019, SV020
SV049
2302 Other than the absolute position detection is connected.
However, the absolute position detection parameter is valid.
SV017, SV025
2303 The servo option is not available.
The closed loop or dual feedback control function is set.
SV025, SV017
2304 The servo option is not available. The SHG control function is
set.
SV057, SV058
2305 The servo option is not available. SV027