Mitsubishi Electronics MDS-R Engraver User Manual


 
8. Setup
8 - 2
8-1 Servo drive unit initial settings
8-1-1 Setting the rotary switch
Before turning the power ON, the axis No. must be set with the rotary switch. The rotary switch settings
will be validated when the units are turned ON.
Rotary switch
setting
Set axis No.
0 1st axis
1 2nd axis
2 3rd axis
3 4th axis
4 5th axis
5 6th axis
6 7th axis
7
8
9
A
B
Not usable
C
D
E
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
L M
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
When MDS-R-V2 Series are used
F Axis not used
POINT
When an axis that is not used is selected, that axis will not be controlled when
the power is turned ON, and "Ab" will remain displayed on the LED. If the power
of the axis not in use is disconnected, the NC system's emergency stop cannot
be released.