Appendix 1. Cable and Connector Specifications
A1 - 24
(6) Inserting the contact
Insert the contact into the specified terminal in the housing.
(Insert grounding wire or drain wire into terminal No.10 in the housing.)
* When the contact catches the housing, you will hear a snap.
(Note) Before inserting the contact, check that the clamp nut, cable clamp, bushing and back shell
is inserted.
Cable
Insert
Contact
Housing
Terminal No.10 only
(Grounding wire or drain wire)
* Insert the contact so that the lance
and the terminal number in the
housing face the same direction.
However, in case of CM 10-AP2S,
insert the contact so that the lance
and the terminal number in the
housing face the opposite direction.
Terminal number
Lance
Contact
Terminal
number
Lance
Contact
CM10-AP2S
(Note) When pulling out a contact, use dedicated jigs and tools.
Contact removal tool:357J-50548T-A