(2) NC bus cable
Wire characteristics Recommended
wire model
(Cannot be
directly ordered
from Mitsubishi
Electric Corp.)
Finished
outside
diameter
Sheath
material
No. of
pairs
Configuration
Conductor
resistance
Withstand
voltage
Insulation
resistance
UL20276 AWG28
10pair
6.1mm PVC 10
7 strands/
0.13mm
222/km or less
AC350/ 1min
1M/km or more
(3) Cable assembly
Assemble the cable with the cable shield wire securely connected to the ground plate of the
connector.
Connect with a ground
plate of connector.
Shield
(external conductor)
Sheath
Core wire
(4) Cable protection tube (noise countermeasure)
If influence from noise is unavoidable, or further noise resistance is required, selecting a flexible
tube and running the signal cable through this tube is effective. This is also an effective
countermeasure for preventing the cable sheath from being cut or becoming worn due to cutting
chips.
A cable clamp (MS3057) is not installed on the detector side, so be particularly careful of broken
wires in applications involving bending and vibration.
Connector
Supplier Tube
Drive unit side Installation screws Motor detector side
Nippon Flex
Control Corp.
FBA-4
(FePb wire braid sheath)
RBC-104 (straight)
RBC-204 (45)
RBC-304 (90)
G16
G16
G16
RCC-104-CA2022
DAIWA DENGYO
CO., LTD
Hi-flex
PT #17 (FePb sheath)
PSG-104 (straight)
PLG-17 (90)
PS-17 (straight)
Screw diameter ø26.4
Screw diameter ø26.4
PF1/2
PDC20-17
Sankei Works
Purika Tube
PA-2 #17 (FePb sheath)
BC-17 (straight) Wire tube screws : 15 PDC20-17
(Note) None of the parts in this table can be ordered from Mitsubishi Electric Corp.