Schneider Electric 372 SPU 780 01EMAN Welding System User Manual


 
Working with the ASCII Editor
372 SPU 780 01EMAN May 2002 211
ASCII Editor
Toolbox
To insert an item either click the corresponding button or press the hot-key. Items
are inserted at the cursor.
Tool Description Button Hot-Key
Text Box Up to 128 characters of text is displayed. T
Binary A placeholder for a binary field. Defined in
ladder logic using a WRIT instruction.
B
Octal A placeholder for an octal field. Defined in
ladder logic using a WRIT instruction.
O
Integer A placeholder for an integer field. Defined in
ladder logic using a WRIT instruction.
I
Hexadecimal A placeholder for a hexadecimal field. Defined
in ladder logic using a WRIT instruction.
H
Leading 0
Integer
A placeholder for a leading 0 integer field.
Defined in ladder logic using a WRIT
instruction.
L
ASCII A placeholder for an ASCII field. Defined in
ladder logic using a WRIT instruction.
A
Space Consecutive blank spaces are displayed. SPACE
Carriage
Return
Moves cursor to the next line. ENTER
Repeat A repeat is denoted by a repeat start ({) and a
repeat end (}). A repeat must have both a start
and an end.
{ - Start
} - End
Control A control character is displayed. CTRL
Flush The message buffer contains a 256 byte data
field. These bytes contain data values ranging
from 00 to FF. The flush command clears all
characters form the message buffer.
BACKSPACE
Flush Num
Bytes
Removes from 1 through 255 bytes from the
beginning of the message buffer.
N/A