Tektronix 070-A830-51 Welding System User Manual


 
Performance Verification
AWG710 Service Manual
4-11
NOTE. The floppy disk file list displayed on the screen does not automatically
update when you replace the diskette with another diskette. To update the file
list, reselect the floppy disk drive.
Table 4–3 lists the sequence and waveform files on the Performance Check/Ad-
justment disk that are used in these performance tests, the AWG710 Arbitrary
Waveform Generator front panel settings that each file sets up, and the perfor-
mance test that uses each file.
NOTE. The files on the Performance Check disk are locked (files are marked by
the icon
in the file list), so the data in these files cannot be changed unless
the lock is opened.
Table 4-3: Waveforms and sequences in performance check disk
No. File name EDIT menu SETUP menu Marker
set p
Usage
Form Points Clock Filter Ampl Offset
se
t
up
1 MODE.WFM 1000 4 GHz Through 1ĂV 0ĂV Marker
1,2: 0 to
499:
High,
500 to
999: Low
Run mode,Trigger level,
Internal trigger accuracy
2 PULSE.WFM 1000 100 MHz Through 1ĂV 0ĂV Pulse response
3 AMP1.SEQ Amplitude accuracy
(Normal out), Marker
4 AMP2.SEQ Amplitude accuracy
(Direct out)
5 DC_P.WFM
(AMPx.SEQ)
1
1000 100 MHz Through 1ĂV 0ĂV Amplitude accuracy
6 DC_M.WFM
(AMPx.SEQ)
1
1000 100 MHz Through 1ĂV 0ĂV Amplitude accuracy
7 DC0.WFM
(AMP2.SEQ)
1000 100 MHz Through 1ĂV 0ĂV Amplitude accuracy
8 OFFSET.WFM 1000 100 MHz Through 20 mV 0ĂV Offset accuracy
Performance
Check/Adjustment Files