Tektronix 070-A830-51 Welding System User Manual


 
Removal and Installation Procedures
AWG710 Service Manual
6-19
You will need a flat-blade screwdriver (Table 6–4, Item 4). Locate the line fuse
and line cord in Figure 6–2.
WARNING. To avoid electrical shock, be sure that the power cord is disconnected
from the socket before checking the line fuse.
1. Orient the generator so the bottom is on the work surface and the rear is
facing you.
2. Disconnect the line cord from the rear panel connector and main power.
3. If you are servicing the line fuse, do the next step; if you are servicing the
line cord, skip to step 5.
4. Find the fuse cap on the rear panel. See Figure 6–7. Remove the fuse cap by
turning it counterclockwise using a flat-blade screwdriver and remove the
line fuse.
5. Find the line cord on the rear cover. See Figure 6–7. Pull the line cord to
complete the removal. Do the procedure in reverse order to install.
6. Do steps 4 and 5 in reverse order to install the line cord and line fuse.
Line Fuse
Fuse Cap
Figure 6-7: Line fuse and line cord removal
Line Fuse and Line Cord