Messages and Codes
6-68
AWG710 Service Manual
Table 6-14: Messages and codes (Cont.)
ErĆ
rorĂcode
SupplementaryĂInformationRelatedĂmoduleErrorĂmessage
1744 CH1 200MHz Filter calibration failure A71 (Output)/A77 (ATT) Check A71 (Output), A77 (ATT) and connection.
1801 CH1 Reference level calibration failure A71 (Output) Check A71 (Output), A77 (ATT) and connection.
1804 CH1 Reference level calibration failure A71 (Output) Check A71 (Output), A77 (ATT) and connection.
/* ---- System Diagnostics ---- */
2100 System failure CPU/Flash Disk/HDD Check CPU/Flash Disk/HDD and connection.
2101 Realtime clock power CPU/Flash Disk/HDD Check CPU/Flash Disk/HDD and connection.
2102 Configuration record and Check-sum staĆ
tus
CPU/Flash Disk/HDD Check CPU/Flash Disk/HDD and connection.
2103 Incorrect configuration CPU/Flash Disk/HDD Check CPU/Flash Disk/HDD and connection.
2104 Memory size miscompare CPU/Flash Disk/HDD Check CPU/Flash Disk/HDD and connection.
2105 Fixed-disk drive initialization status CPU/Flash Disk/HDD Check CPU/Flash Disk/HDD and connection.
2106 Time status CPU/Flash Disk/HDD Check CPU/Flash Disk/HDD and connection.
2110 Front panel failure A20 (Front Panel) Check A20 And connection.
2111 Front panel configuration A20 (Front Panel) Check A20 and connection.
2112 Front panel communication A20 (Front Panel) Check A20 and connection.
2113 Front panel RAM A20 (Front Panel) Check A20 and connection.
2114 Front panel ROM A20 (Front Panel) Check A20 and connection.
2115 Front panel A/D A20 (Front Panel) Check A20 and connection.
2116 Front panel timer A20 (Front Panel) Check A20 and connection.
2700 Calibration data failure Flash Disk Check Flash Disk. Also possible no calibration
after A50/A70 were exchanged.
2701 Calibration data not found Flash Disk Check Flash Disk. Also possible no calibration
after A50/A70 were exchanged.
2702 Calibration data checksum Flash Disk Check Flash Disk. Also possible no calibration
after A50/A70 were exchanged.
2703 Calibration data invalid Flash Disk Check Flash Disk. Also possible no calibration
after A50/A70 were exchanged.
/* ---- Run Mode Diagnostics ---- */
3000 Run mode failure A50 (AWG) Check A50 (AWG).
3100 Run mode Control register0 failure A50 (AWG) Check A50 (AWG).
3101-3108 Run mode control register0 bit0 to bit7 A50 (AWG) Check A50 (AWG).
3200 Run mode control register1 failure A50 (AWG) Check A50 (AWG).
3201 Run mode control register1 reg0 A50 (AWG) Check A50 (AWG).
3211 Run mode control register1 reg10 A50 (AWG) Check A50 (AWG).
/* ---- Clock Diagnostics ---- */
4000 Clock failure A50 (AWG) Check A50 (AWG).