AWG710 Service Manual
1-3
Specifications
This section contains the AWG710 Arbitrary Waveform Generator specifications.
All specifications are guaranteed unless labeled Typical. Typical specifications
are provided for your convenience.
Specifications that are marked with the
n symbol in the Characteristics column
are defined in the Performance erification section. The corresponding page of
the performance verification procedures can be found in the PV reference page
column.
Subcategories of the Characteristics column will appear in boldface font.
See Tables 1–2 through 1–21 for characteristics and descriptions of the electrical
specifications. For signal timing, see Figure 1–1 and for mechanical dimensions,
see Figure 1–2.
Performance limits in this specification are valid under these conditions:
H The AWG710 Arbitrary Waveform Generator must be calibrated/adjusted at
an ambient temperature between +20
_ C and +30_ C.
H The AWG710 Arbitrary Waveform Generator must be in an environment
with temperature, altitude, humidity, and vibration within the operating
limits described in these specifications.
H The AWG710 Arbitrary Waveform Generator must have a warm-up period of
at least 20 minutes.
H The AWG710 Arbitrary Waveform Generator must be operating at an
ambient temperature between +10
_ C and +40_ C.
Warranted characteristics are described in terms of quantifiable performance
limits.
Performance Conditions