Performance Verification
AWG710 Service Manual
4-33
b. Disconnect the adapter, terminator and cable from the CH1 output con-
nector.
c. Connect the adapter, terminator, and cable (removed in step
b) to the CH1
output connector.
d. Push the CH1
output button to turn on the CH1 LED.
e. Push the FORCE EVENT button.
11. Repeat steps 7 through step 9 for the AWG710 Arbitrary Waveform
Generator CH1
.
12. Push the CH1
output button to turn off the CH1 LED.
13. Push the RUN button to turn off the RUN LED.
14. Disconnect the DMM.
Equipment
required
A 50ĂW SMAĂcoaxial cable and an oscilloscope (TDS820).
Prerequisites The AWG710 Arbitrary Waveform Generator must meet the
prerequisites listed on page 4-8.
Do the following steps to install the test hookup and set the test equipment
controls:
1. Use the 50 W SMA coaxial cable to connect the AWG710 Arbitrary
Waveform Generator CH1 output connector to the oscilloscope CH1 input
connector (see Figure 4–13).
AWG710 option 02 Arbitrary Waveform Generator
Oscilloscope (TDS820)
50 W SMAĂcoaxial cable
Figure 4-13: Option 02 output pulse rise time initial test hookup
2. Set the oscilloscope controls as follows:
Vertical......................... CH1
CH1 coupling . ............... DCifapplicable
Check Pulse Rise Time